如何通过GTM Digital monitor读RX Equalizer

描述

有时候在debug GT的时候,需要用Digital monitor读出RX equalizer的code,本篇文章以US+的GTM为例子,提供了一个步骤,详细寄存器可以参考UG581.

Select DRP和Dmonitor port

寄存器

Dmonitor port,用DRP CLK接上Dmonitorclk_in,通过逻辑或者ILA来对dmonitorout_out采样读取。

寄存器

DRP读写寄存器,以CH0为例地址操作如下,CH1的地址将0x0xx改为0x2xx。

CH0:

1)0x082[0] = 1’b1; DMON_ENABLE, Enables digital monitor for channel 0/1.

0x082[2:1] = 2’b00; DMON_SRC, Enables RX DMON path for channel 0/1. Must be set to 2'b00 when reading RX adaptation loops.

0x082[3] =1’b0; DMON_FIFOBYPASS, Enables RX DMON path for channel 0/1. Must set to 1'b0 when reading RX adaptation loops.

2)0x045[13] = 1’b1; Set to 1'b1 when reading DFE adaptation loops.

3)0x033[15] = 1’b0, Set to 1'b0 to read DFE/FFE data.

4)0x033[14:12] =

=3'b100, 选DFE data.

=3'b110, 选FFE data.

读DFE:0x046[15:12]: Selector to monitor DFE adaptation loops for channel 0/1. See output using CH[0/1]_DMONITOROUT port.

a. = 4'b0000; 读[15:3] - H1_BINDACH1_BINDAC

b. = 4'b0001; 读[30:25] - GC_BINDAC;[15:10] - KH_BINDAC

c. = 4'b0010; 读[30:25] - KL_BINDAC;[14:8] - OS_BINDAC

读FFE配置0x05C[13:12]=2’b10;Set to 2'b10 when reading FFE adaptation loops.

读FFE; 0x05C[7:3]:

a. = 5'b00001,读

[28:23] - FFE_HM4

[22:18] - FFE_HP10

[17:13] - FFE_HP09

[12:8] - FFE_HP08

[7:3] - FFE_HP07

b. =5'b00010 读

[31:26] - FFE_HP06

[25:20] - FFE_HP05

[19:13] - FFE_HP04

[12:6] - FFE_HP03

c. = 5'b00011 读

31:24] - FFE_HP02

[23:16] - FFE_HM01

[15:9] - FFE_HM02

[8:3] - FFE_HM03

Channel 1:DRP地址从0x0xx改为0x2xx

• 0x282[0]: DMON_ENABLE

• 0x282[2:1]: DMON_SRC

• 0x282[3]: DMON_FIFOBYPASS

• 0x245[13]: TESTEN

• 0x233[14:12]: DEMONCON

• 0x233[15]: CLKSEL

• 0x25C[13:12]: TESTC

• 0x246[15:12]: DFELOOPSEL

• 0x25C[7:3]: FFELOOPSEL

  审核编辑:汤梓红

打开APP阅读更多精彩内容
声明:本文内容及配图由入驻作者撰写或者入驻合作网站授权转载。文章观点仅代表作者本人,不代表电子发烧友网立场。文章及其配图仅供工程师学习之用,如有内容侵权或者其他违规问题,请联系本站处理。 举报投诉

全部0条评论

快来发表一下你的评论吧 !

×
20
完善资料,
赚取积分