IEC 60870-5-101 在配电自动化系统数据通信中的

消耗积分:5 | 格式:rar | 大小:333 | 2009-03-18

张杰

分享资料个

IEC60870-5-101 在配电自动化系统数据通信中的应用::IEC 60870-5-101 远动规约采用FT1.2 帧格式、链路传输规则及增强性能结构模型,文章分析了配电自动化系统的数据传输特点,论述了该远动规约在配电自动化系统数据传输过程中的应用,描述了规约转换程序设计思想和远动信息网络传输过程。具体分析了规约在实际应用中出现的数据传输优先级、总召唤、遥测越限值设定等问题,并提出了相应的解决方法。
关键词:IEC60870-5-101;配电自动化系统;规约转换;总召唤;电力系统

ABSTRACT: IEC 60870-5-101 telecontrol protocol adopts FT1.2 frame format, link circuit transmission rules and enhance performance architecture model. Here, the data transmission
features in distribution automation (DA) system are analyzed, the application of IEC 60870-5-101 telecontrol protocol in data transmission process of DA system is dissertated, in addition the design philosophy of protocol conversion program and the network transmission process of telecontrol information are described. The concrete analysis on problems occurred in practical application, such as the priority of data transmission, general interrogation and the off-limit value setting in remote measuring, are presented and corresponding solutions are proposed.
KEY WORDS: IEC 60870-5-101;distribution automation
system;protocol conversion;general interrogation;power system

声明:本文内容及配图由入驻作者撰写或者入驻合作网站授权转载。文章观点仅代表作者本人,不代表电子发烧友网立场。文章及其配图仅供工程师学习之用,如有内容侵权或者其他违规问题,请联系本站处理。 举报投诉