This paper designs a phase-shift circuit used to control SCR.Aiming at the problem of noise interference in site, a circuit to get rid of the noise from power system is provided in this paper,and the principle of phase-shift circuit is introduced. The simulation and test results showe that the shift range is from 0° to 178°and the shift resolution is 0.35°/mV.