Solenoid Driver KFD0-SD2-Ex1.1045

型号: KFD0-SD2-Ex1.1045

--- 产品参数 ---

查看更多参数
公司logo

巨匠机械

98內容 |  1.2w浏览量  |  4粉丝

+关注

--- 产品详情 ---

Solenoid Driver KFD0-SD2-Ex1.1045

  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 10 V DC
  • Up to SIL 3 acc. to IEC/EN 61508

提示:以下是本篇文章正文内容,下面案例可供参考

一、产品描述

参数表节选:的技术参数  KFD0-SD2-Ex1.1045

General specifications
Signal typeDigital Output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Supply
Rated voltageloop powered
Power dissipation< 1.05 W (≤ 30 V)
Input
Connection sidecontrol side
Connectionterminals 7, 8
Rated voltage20 ... 35 V DC
Current72 mA at 20 V input voltage, load = 220 Ω
50 mA at 35 V input voltage, load = 220 Ω
Inrush current≤ 200 mA after 100 µs
Output
Connection sidefield side
Connectionterminals 1+, 2-
Internal resistormax. 282 Ω
Current≤ 45 mA
Voltage≥ 10 V
Open loop voltagemin. 22.7 V
Output rated operating current45 mA
Output signalThese values are valid for the rated operating voltage 20 ... 35 V DC.
Energized/De-energized delaysingle operation: typ. 1.7 ms/50 µs; periodical: typ. 5 µs/50 µs
Indicators/settings
Display elementsLED
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility 
 Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2004
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateBASEEFA 06 ATEX 0252
 Marking
Ex-Hexagon

II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C)
 

 Voltage25.2 V
 Current93 mA
 Power590 mW
Input 
 Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
CertificateTÜV 99 ATEX 1499 X
 Marking
Ex-Hexagon

II 3G Ex nA II T4 [device in zone 2]

Galvanic isolation 
 Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity 
 Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approval 
 Control drawing116-0309
UL approval 
 Control drawing116-0316 (cULus)
IECEx approval 
 IECEx certificateIECEx BAS 06.0058
IECEx CML 19.0093X
 IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Ex ec IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

二、应用领域