When an op amp output drives a capacitive load, extra phase shift due to the pole formed by the op amp’s output impedance and the capacitor can cause peaking or even oscillation. The top trace of Figure 6, RS = 0 Ω, shows the output of one of the amplifiers of the AD8072/AD8073 when driving a 50 pF capacitor as shown in the schematic of Figure 7.