HART协议在多变量涡街流量计中的实现

消耗积分:5 | 格式:rar | 大小:113 | 2009-05-30

分享资料个

在传统涡街流量计的基础上,设计出带有HART 通讯协议的多变量涡街流量计。介绍了
HART 协议规范,详细阐述HART 协议在多变量涡街流量计中的软硬件实现方法,并给出系统设计结构和部分硬件电路组成。
关键字:HART 协议,通讯,涡街流量计
Realization of HART protocol in multi-variable vortex flowmeter Ma Yong-cheng Mo De-ju (Information Science and Technology Department, Beijing University of Chemical Technology Beijing, 100029) Abstract:On the basis of traditional vortex flowmeter,a multi-variable vortex flowmeter based on HART communication protocol is designed. The criterion of HART protocol is introduced, and the design method of software and hardware is described for implementing HART protocol communication in multi-variable vortex flowmeter. The structure of system and partial circuit of hardware is present.
Keyword: HART protocol, communication, vortex flowmeter