LM1042 Fluid Level Detector General Description The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is provided proportional to fluid level and single shot or repeating measurements may be made. All supervisory requirements to control the thermal-resistive probe, including short and open circuit probe detection, are incorporated within the device. A second linear input for alternative sensor signals may also be selected. Features Y Selectable thermal-resistance or linear probe inputs Y Control circuitry for thermal-resistive probe Y Single-shot or repeating measurements Y Switch on reset and delay to avoid transients Y Output amplifier with 10 mA source and sink capability Y Short or open probe detection Y a50V transient protection on supply and control input Y 7.5V to 18V supply range Y Internally regulated supply Y b40§C to a80§C operation